乐泰loctite EA9359.3胶水飞机专用胶资料
乐泰loctite EA9359.3胶水飞机专用胶资料:
本文来自:汉高乐泰胶水(中国)有限公司 Henkel Loctite官网 www.loctite.net/c1236.html
Technical Process Bulletin
LOCTITE EA 9359.3 AERO
Epoxy Paste Adhesive
(KNOWN AS Hysol EA 9359.3)
INTRODUCTION
LOCTITE EA 9359.3 AERO is two-component structural adhesive which exhibits high peel and high tensile lapshear strength. It contains 5 mil/0.13 mm glass beads for bondline thickness control. This adhesive hasexcellent resistance to water, salt spray and most organic fluids. A variety of substrates such as metals,thermoplastics and composites may be bonded using LOCTITE EA 9359.3 AERO. LOCTITE EA 9359.3AERO is offered in a two to one cartridge with static mixer.
FEATURES
Easy Mix
Good Environmental Resistance
Non Sag
High Shear Strength
Bondline Thickness Control
High Peel Strength
Available in 2:1 Dual Cartridge with Static Mixer
Uncured Properties
Part A Part B Mixed
Color Yellow Blue Green
Viscosity @ 77°F 2,000 Poise 1,000 Poise
Brookfield, HBT Spdl 7 @ 20 rpm Spdl 6 @ 20 rpm
Viscosity @ 25°C 200 Pa·S 100 Pa·S
Brookfield, HBT Spdl 7 @ 2.1 rad/s Spdl 6 @ 2.1 rad/s
Density (g/ml) 1.16 1.01 1.12
Shelf life@ 77°F/25°C 1 year 1 year
This material will normally be shipped at ambient conditions, which will not alter our standard warranty,provided that the material is placed into its intended storage upon receipt. Premium shipment is available uponrequest.
Mix Ratio Part A Part B
By Weight 100 44
By Volume 2 1
Note: Volume measurement is not recommended for structural applications unless special precautions aretaken to assure proper ratios.
1 of 4
Technical Process Bulletin
LOCTITE EA 9359.3 AERO
Epoxy Paste Adhesive
(KNOWN AS Hysol EA 9359.3)Pot Life
100 gram mass 60 minutes @ 77°F/25°C
200 gram mass 50 minutes @ 77°F/25°C
450 gram mass 40 minutes @ 77°F/25°C
Method - ASTM D2471 in water bath
Peak Exotherm (450 gram mass) is >300°F/149°C @ 40 minutes.
Handling
Mixing - This product requires mixing two components together just prior to application to the parts to bebonded. Complete mixing is necessary. The temperature of the separate components prior to mixing is notcritical, but should be close to room temperature (77°F/25°C).
Application
Mixing - Combine Part A and Part B in the correct ratio and mix thoroughly. THIS IS IMPORTANT! Heatbuildup during or after mixing is normal. Do not mix quantities greater than 450 grams as dangerous heatbuildup can occur causing uncontrolled decomposition of the mixed adhesive. TOXIC FUMES CAN OCCUR,RESULTING IN PERSONAL INJURY. Mixing smaller quantities will minimize the heat buildup.
Applying - Bonding surfaces should be clean, dry and properly prepared. For optimum surface preparationconsult the LOCTITE Surface Preparation Guide. The bonded parts should be held in contact until theadhesive is set. Handling strength for this adhesive will occur in 24 hours (>77°F/25°C), after which thesupport tooling or pressure used during cure may be removed. Since full bond strength has not yet beenattained, load application should be small at this time.
Curing - This adhesive may be cured for 5 to 7 days @ 77°F/25°C to achieve normal performance.Accelerated cures up to 200°F/93°C (for small masses only) may be used as an alternative. For example, 1hour @ 180°F/82°C will give complete cure.
Cleanup - It is important to remove excess adhesive from the work area and application equipment before ithardens. Denatured alcohol and many common industrial solvents are suitable for removing uncuredadhesive. Consult your supplier's information pertaining to the safe and proper use of solvents.
Bond Strength Performance
Tensile Lap Shear Strength
Tensile lap shear strength tested per ASTM D1002 after curing for 7 days @ 77°F/25°C. Adherends are 2024-T3 AlClad aluminum, phosphoric acid anodized per ASTM D3933.
Typical Results
Test Temperature, °F/°C psi MPa
-67/-55 4,000 27.6
77/25 4,500 31.0
180/82 2,000 13.8
200/93 1,000 6.9
2 of 4
Technical Process Bulletin
LOCTITE EA 9359.3 AERO
Epoxy Paste Adhesive
(KNOWN AS Hysol EA 9359.3)Peel Strength
T-Peel strength tested per ASTM D1876 after curing for 7 days @ 77°F/25°C. Adherends are 2024-T3 AlCladaluminum, phosphoric acid anodized per ASTM D3933.
Typical Results
Test Temperature, °F/°C Lb/in N/25 mm
77/25 60 267
Service Temperature
Service temperature is defined as that temperature at which this adhesive still retains 1000 psi (6.9 MPa) usingtest method ASTM D1002 and is approximately 200°F/93°C.
Bulk Resin Properties
Tensile Properties- tested using 0.125 inch/3.18 mm castings per ASTM D638. Adhesive cure 5 days @77°F/25°C and 1 hour @ 200°F/93°C.
Tensile Modulus @ 77°F/25°C 310 ksi 2136 MPa
Elongation at Break @ 77°F/25°C 7.7%
Shear Modulus, dry @ 77°F/25°C (by RDS) 149 ksi 1027 MPa
Shear Modulus, wet @ 77°F/25°C (by RDS) 89 ksi 613 MPa
Dry Wet1
Tg (Tan Delta by DMTA) @ 77°F/25°C cure 134°F/51°C 150°F/66°C
Tg (Tan Delta by DMTA) @ 200°F/93°C cure 185°F/85°C 149°F/65°C
1Wet exposure: 30 days @ 160°F/71°C, 95% RH
Thermal Conductivity - Tested per ASTM E1461
Specific Heat, J/g 0.93
Conductivity, W/mK 0.24
Compressive Properties- tested using 0.5 inch x 1 inch (12.7 x 25.4 mm) right cylinders @ 77°F/25°C perASTM D695.
Compressive Strength cured @ 77°F/25°C 7,700 psi 53.0 MPa
Compressive Strength cured @ 200°F/93°C 21,000 psi 145 MPa
Handling Precautions
Do not handle or use until the Material Safety Data Sheet has been read and understood.
For industrial use only.
DISPOSAL INFORMATION
Dispose of spent remover and paint residue per local, state and regional regulations. Refer to HENKELTECHNOLOGIES MATERIAL SAFETY DATA SHEET for additional disposal information.
3 of 4
Technical Process Bulletin
LOCTITE EA 9359.3 AERO
Epoxy Paste Adhesive
(KNOWN AS Hysol EA 9359.3)PRECAUTIONARY INFORMATION
General:
As with most epoxy based systems, use this product with adequate ventilation. Do not get in eyes or on skin.Avoid breathing the vapors. Wash thoroughly with soap and water after handling. Empty containers retainproduct residue and vapors so obey all precautions when handling empty containers.
PART A
CAUTION!This material may cause eye and skin irritation or allergic dermatitis. It contains epoxy resins.PART B
WARNING!This material causes eye and skin irritation or allergic dermatitis. It contains amines.
Before using this product refer to container label and HENKEL TECHNOLOGIES MATERIAL SAFETY DATASHEET for additional precautionary, handling and first aid information.
Note
The data contained herein are furnished for information only and are believed to be reliable. We cannotassume responsibility for the results obtained by others over whose methods we have no control. It is theuser's responsibility to determine suitability for the user's purpose of any production methods mentioned hereinand to adopt such precautions as may be advisable for the protection of property and of persons against anyhazards that may be involved in the handling and use thereof. In light of the foregoing,Henkel Corporationspecifically disclaims all warranties expressed or implied, including warranties of merchantability orfitness for a particular purpose, arising from sale or use of Henkel Corporation’s products. HenkelCorporation specifically disclaims any liability for consequential or incidental damages of any kind,includinglost profits.The discussion herein of various processes or compositions is not to be interpreted asrepresentation that they are free from domination of patents owned by others or as a license under any HenkelCorporation patents that may cover such processes or compositions. We recommend that each prospectiveuser test his proposed application before repetitive use, using this data as a guide. This product may becovered by one or more United States or foreign patents or patent applications.
Rev. 7/2013
Henkel Corporation Aerospace | 2850 Willow Pass Road | Bay Point, CA 94565
PHONE: +1.925.458.8000 | FAX: +1.925.458.8030| www.loctite.net/cs-xinwenzhongxin1.html
Trademark usage
Except as otherwise noted, all trademarks in this document are trademarks of Henkel Corporation in the U.S. and elsewhere. ® denotes a trademark
registered in the U.S. Patent and Trademark Office.
The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained
by others over whose methods we have no control. It is the user's responsibility to determine suitability for the user's purpose of any production
methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that
may be involved in the handling and use thereof. In light of the foregoing,Henkel Corporationspecifically disclaims all warranties expressed or
implied,including warranties of merchantability or fitness for aparticular purpose, arising from sale or use of Henkel Corporation’s
products. Henkel Corporation specifically disclaims any liability for consequential or incidental damages of any kind, including lost profits.
The discussionherein of various processes or compositions is not to beinterpreted as representation that they are free fromdomination of patents
owned by others or as a license underany Henkel Corporation patents that may cover suchprocesses or compositions. We recommend that each
prospective user test his proposed application before repetitive use, using this data as a guide. This product may be covered by one or more United
States or foreign patents or patent applications.
4 of 4