乐泰loctite3331UV胶水中文参数资料用途
乐泰loctite3331UV胶水中文参数资料用途 :
本文来自:汉高乐泰胶水(中国)有限公司 Henkel Loctite官网 www.loctite.net/c1174.html
TechnicalDataSheet
LOCTITE® 3331™
November-2004PRODUCTDESCRIPTION TYPICALPROPERTIESOFCUREDMATERIAL
LOCTITE® 3331™ provides the following product Cured@120mW/cm² @365nmfor 30 seconds usingacharacteristics: mediumpressure mercuryarclightsource
Technology Acrylic PhysicalProperties:
ChemicalType Acrylatedurethane ShoreHardness, ISO868,Durometer D 66
LMS RefractiveIndex 1.5Appearance(uncured) Transparentliquid WaterAbsorption,ISO62,%:
Components One component - requiresnomixing 2 hoursinboilingwater 11Viscosity Low Elongation,atbreak,ISO527,% 82Cure Ultraviolet(UV)light TensileModulus,ISO527 N/mm² 448CureBenefit Production-highspeedcuring (psi) (65,000)Application Bonding TensileStrength,atbreak,ISO527 N/mm² 20.3Flexibility Enhances load bearing & shock (psi) (2,950)
absorbingcharacteristicsofthebond UVDepthofCure,mm:
area. LMS
6 mW/cm² @365nm for 3minutes ≥0.75
® 120 mW/cm² @365nm for 15seconds 3.8LOCTITE 3331™isdesignedprimarilyfor bondingheavily
plasticizedPVC.Thisproducthasalso shown goodadhesion Electrical Properties:
tootherthermoplastics, suchaspolycarbonateandABS. SurfaceResistivity,IEC60093,Ω 5.33×1014
VolumeResistivity,IEC60093,Ω·cm 1.48×1015TYPICALPROPERTIESOFUNCUREDMATERIAL DielectricBreakdownStrength,IEC60250,kV/mm 26SpecificGravity@ 25°C 1.06 DielectricConstant/DissipationFactor,IEC60250:
RefractiveIndex 1.47 100-Hz 4.88/0.03FlashPoint-SeeMSDS 1-kHz 4.66/0.02Viscosity,Brookfield -RVT, 25°C,mPa·s(cP): 1-MHz 4.04/0.03Spindle2,speed20rpm 360 to825LMS
TYPICALCURINGPERFORMANCE TYPICALPERFORMANCEOFCUREDMATERIAL
® AdhesiveProperties
LOCTITE 3331™canbecuredby exposureto UV and/or
visible light of sufficient intensity. To obtain full cure on Cured@120mW/cm² @365nmfor 15 seconds usingsurfacesexposedtoair,radiation@220to260nmisalso a highpressure mercuryarclightsource
required.ThespeedofcurewilldependupontheUVintensity BlockShearStrength,ISO13445:
andspectraldistributionofthelightsource,theexposuretime PVC toGlass N/mm² *6.1andthelighttransmittanceofthesubstrates. (psi) (880)StressCracking *substratefailure
Liquidadhesive isappliedtoamedical gradepolycarbonate TYPICALENVIRONMENTAL RESISTANCE
bar6.4cmby13mmby3mmwhichhadbeenflexedtoinduce
aknownstresslevel. Cureidm@pr1e2s0sumreW /cemrc²u @ya3rc65lignhmtsfor 15 seconds usingaStressCracking,ASTMD3929,minutes:
12N/mm²stressonbar ≥15 BlockShearStrength,ISO13445:
FixtureTime PVC toGlass
Fixturetimeisdefinedasthetimetodevelopashearstrength
of0.1N/mm². Chemical/SolventResistance
UVFixtureTime,ISO4587,Glassmicroscopeslides,seconds: Agedunderconditionsindicatedandtested @22°C.
® %ofinitialstrength
Blacklight,Zeta 7500lightsource:
6 mW/cm²@365nm ≤5LMS
Environment °C 2h 24h 170h
Air 71 ------- ------- 100UVFixtureTime,ISO4587,Polycarbonate,seconds: Air 93 ------- ------- 100
Mediumpressure mercuryarclightsource: Boilingwater 100 100 -------- --------
120 mW/cm² @365nm <5 Waterimmersion 48 -------- -------- 55
Waterimmersion 87 ------- ------- 0
IPAimmersion 22 -------- 100 --------
95%RH 38 ------- ------ 100 TDSLOCTITE®3331™, November-2004EffectsofSterilization Conversions
® (°Cx1.8)+32=°F
In general, products similiar in composition to LOCTITE kV/mmx25.4=V/mil
3331™subjectedtostandardsterilizationmethods,suchas mm/25.4=inches
EtOandGammaRadiation(25to50kiloGrays cumulative) Nx0.225=lb
showexcellentbondstrengthretention. LOCTITE® 3331™
N/mmx5.71=lb/in
maintainsbondstrengthafter1cycleofsteamautoclave. Itis N/mm²x145=psi
recommended that customers test specific parts after MPax145=psi
subjectingthemtotheperferredsterilizationmethod. Consult N·m x 8.851= lb·in
® N·mx0.738=lb·ft
withLoctite foraproductrecommendationifyourdevicewill N·mm x0.142=oz·in
seemorethan3sterilizationcycles. mPa·s=cP
GENERALINFORMATION Note
Thisproductisnotrecommendedforuseinpureoxygen Thedatacontainedhereinarefurnishedfor informationonlyand/oroxygenrichsystemsandshouldnotbeselectedas and are believed to be reliable. We cannot assumeasealantforchlorineorotherstrongoxidizingmaterials. responsibilityfortheresultsobtainedby othersover whoseForsafehandlinginformationonthisproduct,consultthe methodswehavenocontrol. Itistheuser'sresponsibilitytoMaterialSafetyDataSheet(MSDS). determinesuitabilityfortheuser'spurposeofanyproduction
methodsadmveisntiolnefdrhtereeinroatndtitonaodfopprtsurcthprecafutionrssoasDirectionsforuse againstanyhazardsthatmaybeinvolvedinthehandlingand1. Thisproductislight sensitive; exposuretodaylight,UV usethereof. Inlight of theforegoing, HenkelCorporation
lightandartificiallightingshouldbekepttoaminimum specificallydisclaimsallwarrantiesexpressedorimplied,
duringstorageandhandling. including warrantiesof merchantabilityor fitnessfor a2. Theproductshouldbedispensedfromapplicatorswith particular purpose, arising fromsaleoruseof Henkel
blackfeedlines. Corporation’sproducts. HenkelCorporationspecifically3. Forbestperformancebondsurfacesshouldbecleanand disclaims any liability for consequential or incidental
freefromgrease. damagesofanykind,includinglostprofits. Thediscussion4. Curerateisdependentonlampintensity,distancefrom hereinof various processes or compositions is not to be
lightsource,depthofcureneededorbondlinegapand interpreted as representation that they are free from
lighttransmittance ofthesubstrate throughwhich the dominationofpatentsownedbyothersorasalicenseunder
radiationmustpass. any Henkel Corporation patents that may cover such5. Cooling should be provided for temperature sensitive processes or compositions. We recommend that each
substratessuchasthermoplastics. prospectiveusertesthisproposedapplicationbeforerepetitive6. Plastic grades should be checked for risk of stress use,usingthisdataasaguide. Thisproductmaybecovered
crackingwhenexposedtoliquidadhesive. byoneormoreUnitedStatesor foreignpatents or patent7. Excessuncuredadhesivecanbewipedawaywithorganic applications.
solvent(e.g.Acetone). Trademarkusage
8. Bondsshouldbeallowedtocoolbeforesubjecting toany Exceptasotherwisenoted,alltrademarksinthisdocument
serviceloads. are trademarks of Henkel Corporation in the U.S. and
elsewhere. ® denotes atrademarkregisteredintheU.S.LoctiteMaterialSpecificationLMS
LMSdatedAugust-26,1995. Testreportsforeachbatchare PatentandTrademarkOffice.
availablefortheindicatedproperties. LMStestreportsinclude
selected QC test parameters considered appropriate to Reference1
specificationsforcustomeruse. Additionally,comprehensive
controls are in place to assure product quality and
consistency. Specialcustomerspecificationrequirementsmay
becoordinatedthroughHenkel Quality.
Storage
Storeproductintheunopenedcontainer inadry location.
Storageinformationmaybeindicatedontheproductcontainer
labteilingl.Storage: 8°Cto21°C. Storagebelow 8°Cor
greaterthan28°Ccanadverselyaffectproductproperties.
Materialremovedfromcontainersmaybecontaminatedduring
use. Donotreturnproducttotheoriginalcontainer. Henkel
Corporationcannot assumeresponsibilityfor product which
hasbeencontaminatedorstoredunderconditionsotherthan
thosepreviouslyindicated.Ifadditionalinformationisrequired,
please contact your local Technical Service Center or
CustomerServiceRepresentative.
HenkelLoctiteAmericas HenkelLoctiteEurope HenkelLoctiteAsiaPacific+860.571.5100 +49.89.9268.0 +86.20.3623.0506
Forthemostdirectaccesstolocalsalesandtechnicalsupportvisit:www.loctite.net